| Current Transformers (600 Volt, Indoor Window Type) |
| JAI_U-0C |
Model JAI U-0C Standard |
7/31/2007 |
[189k] |
| Model: JAI-0C, JAU-0C. Window Diameter: 1.05", 2.06", 3.00" |
 |
| JAB-0C |
Model JAB-0C Standard |
7/31/2007 |
[299k] |
| Model: JAB-0C; Window Size: 4.50" x 3.50" |
 |
| JAB-0CV |
Model JAB-0C CT for High Temp Applications |
7/31/2007 |
[226k] |
| Model: JAB-0CV (High temperature). Window Size: 4.50" x 3.50" |
 |
| JAB-AC |
Model JAB-AC for High Accuracy Applications |
7/31/2007 |
[171k] |
| Model: JAB-AC (0.15 Class). Window Size: 4.50" x 3.50" |
 |
| JAB-0C_MT |
Model JAB-0C Multiple Taps |
7/31/2007 |
[181k] |
| Model: JAB-0C; Multi-Tap. Window Size: 4.50" x 3.50" |
 |
| JAH-0C |
Model JAH-0C Standard |
7/31/2007 |
[273k] |
| Model: JAH-0C; Window Size: 4.00", 5.00" |
 |
| JAS-0C |
Model JAS-0C Standard |
7/31/2007 |
[146k] |
| Model: JAS-0C; Window Size: 4.00" |
 |
| JCS-0C |
Model JCS-0C Standard |
7/31/2007 |
[168k] |
| Model: JCS-0C; Window Size: 2.50",4.88",5.25"; Recommended replacement for JAF-0 |
 |
| JCB-0CC |
Model JCB-0CC Standard |
7/31/2007 |
[145k] |
| Model: JCB-0CC; Window Size: 7.25", 8.13" |
 |
Current Transformers (600 Volt, Indoor Bar Type) |
| CTM-0C-1 |
Single Bar CTM-0C |
6/15/2009 |
[104k] |
| Model: CTM-0; Single Bar 600V, 10kV BIL, 50-1200A; wound primary |
 |
| CTM-0C-2 |
Double Bar CTM-0C |
6/15/2009 |
[85k] |
| Model: CTM-0; Double Bar 600V, 10kV BIL, 50-1200A; wound primary |
 |
| JCT-AC |
Model JCT-AC for High Accuracy Applications |
2/26/2009 |
[91k] |
| Model: JCT-0C |
 |
| JCT-0C |
Model JCT-0C Standard |
7/31/2007 |
[179k] |
| Model: JCT-0C |
 |
| JCM-0C |
Model JCM-0C Standard |
7/31/2007 |
[169k] |
| Model: JCM-0C |
 |
| JCA-0C |
Model JCA-0C Standard |
7/31/2007 |
[210k] |
| Model: JCA-0C |
 |
Current Transformers (600 Volt, Indoor / Outdoor) |
| JAD-0C |
Model JAD-0C Standard |
7/31/2007 |
[260k] |
| Model: JAD-0C |
 |
| JAD-AC |
Model JAD-AC for High Accuracy Applications |
7/31/2007 |
[236k] |
| Model: JAD-AC (0.15 Class) |
 |
| JAD-0C_X |
Model JAD-0C with Cross Shaped Window |
7/31/2007 |
[170k] |
| Model: JAD-0C; Window: Cross Shape |
 |
| JAK-0C |
Model JAK-0C Standard |
7/31/2007 |
[321k] |
| Model: JAK-0C; Window Size 1.50", 2.60", 3.06" |
 |
| JAK-AC |
Model JAK-AC for Hight Accuracy Applications |
7/31/2007 |
[291k] |
| Model: JAK-AC;(0.15 Class). Window Size 1.50", 2.60", 3.06" |
 |
| JCR-0C |
Model JCR-0C Standard |
7/31/2007 |
[210k] |
| Model: JCR-0C; Window Size 1.13", 1.50", 2.00" |
 |
| JCW-0C |
Model JCW-0C Standard |
7/31/2007 |
[227k] |
| Model: JCW-0C; Window Size 1.13", 1.50", 2.00" |
 |
| JCP-0C |
Model JCP-0C Standard |
7/31/2007 |
[150k] |
| Model: JCP-0C; Window Size 5.38" |
 |
| JCD-0C |
Model JCD-0C |
7/31/2007 |
[148k] |
| Model: JCD-0C; Window Size 8.13" |
 |
Current Transformers (600 Volt, Encompass) |
| JAB-0W |
Model JAB-OW Encompass Extended Range |
7/31/2007 |
[153k] |
| Model: JAB-0W; Window Size: 4.50" x 3.50" |
 |
| JAD-0W |
Model JAD-OW Encompass Extended Range |
7/31/2007 |
[249k] |
| Model: JAD-0W; Window Size: 5.75" |
 |
| JAK-0W |
Model JAK-OW Encompass Extended Range |
7/31/2007 |
[173k] |
| Model: JAK-0W; Window Size: 3.06" |
 |
| JCR-0W |
Model JCR-OW Encompass Extended Range |
7/31/2007 |
[168k] |
| Model: JCR-0W; Window Size: 2.00" |
 |
Auxiliary Transformer (600 Volt, Indoor) |
| JAR-0C |
Model JAR-0C Auxiliary CT |
7/31/2007 |
[165k] |
| Model: JAR-0C; Auxiliary CT |
 |
Voltage Transformers (600 Volt) |
| PTM-0C |
PTM-0C Indoor/Outdoor Voltage Transformer |
6/15/2009 |
[104k] |
| Model: PTM-0; 10kV BIL, 600V |
 |
| JVA-0C |
Model JVA-0C Outdoor VT |
7/31/2007 |
[196k] |
| Model: JVA-0C; 300 VA; Outdoor |
 |
| JE-27C |
Model JE-27C Indoor VT |
7/31/2007 |
[389k] |
| Model: JE-27C |
 |
| JEV-0C |
Model JEV-0C Indoor VT |
7/31/2007 |
[232k] |
| Model: JEV-0C |
 |
| JVM-0C |
Model JVM-0C Indoor VT |
7/31/2007 |
[356k] |
| Model: JVM-0C |
 |
Current Transformers (Medium Voltage, Outdoor) |
| JKW-5C |
Model JKW-5C 15kV Outdoor CT with RF 1.5 for Relaying |
2/25/2009 |
[85k] |
| Model: JKW-5C; 110kV BIL, 5 to 1200 A; 14.55" x 12.37" x 10.88" (370mm x 314mm x 276mm) |
 |
| JKW-6C |
Model JKW-6C 25kV Outdoor CT with RF 1.5 for Relaying |
7/14/2009 |
[72k] |
| Model: JKW-6C; 150kV BIL, 10 to 1200 A; 18.59" x 13.13" x 11.56" (472mm x 333mm x 294mm) |
 |
| JKW-7C |
Model JKW-7C 34.5kV Outdoor CT with RF 1.5 for Relaying |
7/14/2009 |
[72k] |
| Model: JKW-7C; 200kV BIL, 10 to 1200 A; 18.59" x 13.13" x 11.56" (472mm x 333mm x 294mm) |
 |
| JCK-5C |
Model JCK-5C 15kV Outdoor CT with RF 3.0 for Metering |
2/25/2009 |
[87k] |
| Model: JCK-5C; 110kV BIL, 5 to 1200 A; 14.55" x 12.37" x 10.88" (370mm x 314mm x 276mm) |
Current Transformers (Medium Voltage, Indoor) |
| JKM-3C |
Model JKM-3C 5kV Indoor CT |
7/31/2007 |
[207k] |
| Model: JKM-3C |
 |
| JKM-4C |
Model JKM-4C 8.7kV Indoor CT |
7/31/2007 |
[176k] |
| Model: JKM-4C |
 |
| JKM-5C |
Model JKM-5C 15kV Indoor CT |
7/31/2007 |
[216k] |
| Model: JKM-5C |
 |
| JKM-5AC |
Model JKM-5AC for High Accuracy Applications |
7/31/2007 |
[185k] |
| Model: JKM-5AC |
 |
Voltage Transformers (Medium Voltage, Indoor) |
| JVM-2C_3C |
Model JVM-5C 2.4-4.8kV Indoor VT |
7/31/2007 |
[206k] |
| Model: JVM-2C_3C |
 |
| JVM-4C_5C |
Model JVM-5C 8.7-15kV Indoor VT |
7/31/2007 |
[269k] |
| Model: JVM-4C_5C |
 |
| JVM-4AC_5AC |
Model JVM-5AC 8.7-15kV Indoor VT for High Accuracy |
7/14/2009 |
[86k] |
| Model: JVM-4AC, JVM-5AC |
 |
| JVM-6C |
Model JVM-6C 25kV Indoor VT |
7/31/2007 |
[185k] |
| Model: JVM-6C |
 |
|