Digital Energy  Power Quality  Automatic Transfer Switch
ZBTS - Standard (Open) Transition
 
ZBTS - Standard (Open) Transition

In business and industrial critical applications power cannot be interrupted to perform maintenance of automatic transfer switches. In such circumstances, a bypass-isolation switch is essential and is often required by code.

Zenith ZBTS Series Bypass-Isolation Transfer Switches are the solution when interruption of power during service or testing is not acceptable.

Consisting of two major modules-the Automatic Transfer (ATS) and the Bypass-Isolation Switch-the ZBTS Series incorporates the rugged construction of all our ZTS Series automatic switches with a quick make/quick break bypass switch manual load transfer handle and our control/interlock system, which consists of both mechanical and electrical interlocks.

The bypass uses normal failure sensing and a time delay to start the engine automatically if a failure occurs when the ATS has been removed for service-which can be done without disturbing the load.

Configurations
  • ZBTS - Standard (Open) Transition Bypass/Isolation
    The Zenith ZBTS Bypass/Isolation transfer switch is used in general and mixed load applications.
  • ZBTSD - Delayed Transition Bypass/Isolation
    The Zenith ZBTSD Bypass/Isolation transfer switch is used to transfer of large motor loads, transformers, uninterruptible power supplies (UPS) systems or load shedding to a neutral "center" position.
  • ZBTSCT - Closed Transition Bypass/Isolation
    The Zenith ZBTSCT Bypass/Isolation transfer switch is used to transfer critical loads where a "no break" transfer is desired with this switch 100msec parallel capability.
  • Features and Benefits
  • Load is not interrupted during bypass & isolation operation
  • High close-in and withstand capacity
  • Automatic transfer switch is located on a draw-out mechanism to facilitate maintenance
  • Emergency power systems can be electrically tested without disturbing the load
  • Power cables do not have to be disconnected to remove automatic transfer switch
  • Bypass to any available source with ATSremoved
  • Engine start circuit maintained during bypass operation; normal power failure causes engine start contact closure even with the ATS removed
  • Diagnostic lights and detailed instructions for simple step-by-step operation
  • Mechanical and electrical interlocks ensure proper sequence of operation
  • Bypass switch contacts are closed only during the bypass-isolation operation
  • Silverplated copper bus interconnection of the transfer and bypass switches on all sizes
  • Specifications
  • Temperature rise test per UL 1008 conducted after overload and endurance tests in unventilated enclosure-exceeds UL requirements
  • UL 1008 listed at 480 VAC
  • CSA C22.2 No. 178 certified at 600 VAC
  • IEC 947-6-1 listed at 480 VAC
  • Seismic certified to IEEE-693-2005 at HIGH level with 2.5 amplification factor
  • Seismic certified to IBC-2006 at Ip=1.5 for z/h less than or equal to 1
  • Product Scope
  • Ratings 100 to 4000 amperes
  • 2, 3 or 4 poles
  • Open type, NEMA 1, 3R, 4, 4X and 12
  • Bypass and automatic transfer switch have identical ratings
  • Suitable for emergency and standby applications on all classes of load, 100% tungsten rated through 400 amps
  • Available in ZBTS (utility-generator), ZBTSU (utility-utility), ZBTSG (generator-generator) and ZBTSM (manual) configurations