G30 Generator Management Relay | The G30 Generator Management Relay, part of the UR family of protective relays, is a microprocessor-based relay intended for the protection of small generators and for applications needing combined generator and transformer protection.
Protection functions include restricted ground fault (zero sequence differential), split phase protection, differential protection (In-Zone Transformer protection), loss of excitation, sensitive directional ground, current unbalance, overcurrent protection, overexcitation protection, abnormal voltage frequency protection, synchronism check, and a whole suite of under- and overvoltage, and overcurrent functions.
What's New in the G30:
Fully Compatible with GE's Multlilin HardFiber System - Provides support for GE's IEC 61850 HardFiber Process Bus Solution:
- Complete IEC61850 Process Bus Solution providing resource optimization and minimizing total P&C lifecycle costs
Security Enhancements - Enabling NERC CIP compliance:
- Dual Permission access requiring live permission from both the user and from SCADA operators before settings can be changed or commands can be given to the relay
- Logging of user commands in the security audit trail relay - creates a record and sequence of events for troubleshooting and security auditing
Ambient Temperature Monitoring:
- Provides alarms when the ambient temperature exceeds hot extreme
Features and Benefits FlexLogic™ programmable logic Virtual I/Os (reduce hardware cost) Expandable I/Os Flash memory for field upgrades Optional user programmable pushbuttons User programmable LEDs, fault reports, display messages, and self tests Drawout modules for serviceability Common modules (reduce spare cost) Test mode for I/Os IRIG-B time synchronization Applications Small generators Backup protection for the G60 Combined generator and transformer protection Stand-alone or component in automated substation control system Supports multiple system configurations Protection and Control In-Zone transformer protection Synchronism check Restricted ground fault Split phase protection Loss of excitation Reverse and low forward power Current unbalance Phase, ground, neutral and negative-sequence IOC and TOC Phase and neutral directional IOC Over excitation Over and undervoltage Over and underfrequency Voltage transformer fuse failure Phase sequence reversal for pump storage applications Tripping without Logic for direct tripping without the need for configuring Flexlogic Equations Double Point Breaker/Switch Status Support for Third Harmonic Monitoring and Metering Current, voltage, power, power factor, frequency, energy Multiple fault reports Contact input and output status Transducer I/Os 64 samples/cycle programmable oscillography 1024 programmable event recorder 16 channels programmable data logger Self diagnostic
User Interface 2 x 20 character front panel display and keypad for local access 48 programmable LED indicators User-programmable pushbuttons providing local control Multi-language support - French, Chinese, Russian options Communications
Front Panel RS232 port Up to two RS485 ports (up to 115 kbps) Ethernet port: Redundant 10BaseFL or 100BaseFX fiber optics Embedded Ethernet Switch for direct networking of UR devices Inter-relay communications interfaces, RS422, G.703, IEEE C37.94 Direct I/O - Exchange inputs and outputs between relays with reduced wiring Modbus RTU and TCP/IP IEC61850 DNP 3.0 RTU and TCP/IP IEC60870-5-104 Ethernet Global Data (EGD)
Security
Remote and Local Setting and Control passwords Configurable lockout responses to unsuccessful password access attempts Successful password access logged in Event Record
|