N60 Network Stability and Synchrophasor Measurement System


N60 Network Stability and Synchrophasor Measurement System

 

The N60 Network Stability and Synchrophasor System is a flexible device intended for the development of load shedding, Remedial Action, special protection schemes and wide area monitoring (synchrophasors). Special protection schemes are unique to each installation and are carefully matched to a given system topology, operating practices, system and protection philosophies of a given utility. The N60 provides an exceptionally flexible platform to easily integrate and facilitate special protection schemes.

What's New in the N60:

Breakthrough on Synchrophasors allows PMU transmission through IEC 61850 GOOSE messages and direct analog outputs
Two new concepts “GOOSE and Direct Synchrophasors” allow the Multilin N60 to concentrate synchrophasors from up to 4 different local devices using IEC 61850 GOOSE and retransmit them to remote substations through direct I/O using existing communications channels (64/128kbps).
- “GOOSE Synchrophasor” uses IEC 61850 GOOSE as the transmission protocol for sending PMU data within the substation
- “Direct Synchrophasor” uses inter-relay communication modules (direct I/O) and existing low-bandwidth communication channels to transmit synchrophasor data to and from remote substations. (firmware version 5.70)
Fully Compatible with GE's Multlilin HardFiber System - Provides support for GE's IEC 61850 HardFiber Process Bus Solution:
- Complete IEC61850 Process Bus Solution providing resource optimization and minimizing total P&C lifecycle costs
Security Enhancements - Enabling NERC CIP compliance:
- Dual Permission access requiring live permission from both the user and from SCADA operators before settings can be changed or commands can be given to the relay
- Logging of user commands in the security audit trail relay - creates a record and sequence of events for troubleshooting and security auditing
Ambient Temperature Monitoring:
- Provides alarms when the ambient temperature exceeds hot extreme

Features and Benefits
  • Decrease blackouts - By identifying network instabilities and taking fast preventative action
  • Higher utilization of existing investments - Increase power transfer capability on existing lines
  • Increase power system performance - Decisions & control based on fast communications, and information exchange
  • Optimized data sharing and utilization - Complements existing control & protection by sharing information with existing systems for enhanced power system security
  • Contingency planning through continuous synchrophasor data collection and postmortem analysis
  • Reliable and secured network - Improved state estimation for SCADA for optimum system wide load shedding and remedial action schemes
  • Enhanced and automated mitigation for system critical conditions such as power system dampening and loss of synchronism reducing outages
  • GOOSE Synchrophasor – PMU transmission over IEC61850 and Goose messages
  • Direct Synchrophasor – PMU transmission via a low bandwidth communication channel (68-128kbps) with UR direct I/O
  • FlexLogic™ programmable logic
  • Virtual I/O (reduce hardware cost)
  • Expandable I/O
  • Flash memory for field upgrades
  • Optional user programmable pushbuttons
  • User programmable LEDs, fault reports, display messages, and self tests
  • Drawout modules for serviceability
  • Common modules (reduce spare cost)
  • Test mode for I/Os
  • IRIG-B time synchronization and repeater
  • Increased GOOSE performance - transmit analog GOOSE messages up to a rate of every 250ms
Protection and Control
  • Underfrequency, overfrequency and rate of change of frequency (df/dt)
  • Out-of-step tripping and power swing blocking
  • Synchrocheck
  • Overvoltage, undervoltage
  • Tripping without Logic for direct tripping without the need for configuring Flexlogic Equations
  • Double Point Breaker/Switch Status
Communications
  • Streaming phasors over Ethernet - rates from 1 to 60 Phasors/sec
  • Direct I/O - exchange of binary data between URs with additional tools to allow exchange of analog data
Monitoring and Metering
  • Synchrophasor Recording - 25MB memory with multiple recording options an trigger options
  • Metering - current, voltage, power, energy, frequency, demand (current, power)
  • DataLogger - Up to 16 channels with user selectable sampling rate
User Interface
  • 2 x 20 character front panel display and keypad for local access
  • 48 programmable LED indicators
  • User-programmable pushbuttons providing local control
  • Multi-language support - French, Chinese, Russian options
  • EnerVista™ UR Setup software for configuration, monitoring and troubleshooting
Communications
  • Front Panel RS232 port
  • Up to two RS485 ports (up to 115 kbps)
  • Ethernet port: Redundant 10BaseFL or 100BaseFX fiber optics
  • Embedded Ethernet Switch for direct networking of UR devices
  • Inter-relay communications interfaces, RS422, G.703, IEEE C37.94
  • Direct I/O - Exchange inputs and outputs between relays with reduced wiring
  • Modbus RTU and TCP/IP
  • IEC61850
  • DNP 3.0 RTU and TCP/IP
  • IEC60870-5-104
  • Ethernet Global Data (EGD)
Security
  • Remote and Local Setting and Control passwords
  • Configurable lockout responses to unsuccessful password access attempts
  • Successful password access logged in Event Record