| Microgrid Control System |
 |
 |
GE's Grid IQ™ Microgrid Control System enables distribution grid operators to integrate and optimize energy assets (electrical and/or thermal) to reduce the overall energy cost for the local distribution grid, known as a "microgrid". The Microgrid Control System is based on a supervisory control architecture provided by the Multilin™ U90Plus Generation Optimizer, intelligent electronic devices (IEDs), substation gateways and a secure communications network.

More Info |
 |
| C60 Breaker Protection System |
 |
 |
Integrated breaker monitoring and control for substation automation. The C60, a member of the UR Family, is a substation hardened controller that provides a complete integrated package for the protection, control, and monitoring or circuit breakers within a substation. The C60 provides fast and deterministic execution of programmable logic necessary for substation automation applications.

More Info Buy Now |
 |
| C30 Controller System |
 |
 |
Substation hardened, relay grade programmable logic controller. The C30, a member of the UR Family, is a digital IED designed to act as a substation hardened programmable logic controller that can also expand the I/O capability of protection devices and replace existing Sequence of Events (SOE) Recorders. The C30 provides fast and deterministic execution of programmable logic with I/O capabilities far above an average protection relay.

More Info Buy Now |
 |
| N60 Network Stability and Synchrophasor Measurement System |
 |
 |
Load shedding, remedial action and special protection schemes. The N60 Network Stability and Synchrophasor Measurement System, a member of the UR Family of protection relays, is a flexible device
intended for the development of load shedding and special protection schemes.

More Info Buy Now |
 |
| C90Plus Automation Control System |
 |
 |
The C90Plus Automation Control System with fast load shed is a powerful automation control system that eliminates the need for several separate devices. Performing intelligent high-end and fast optimal load shedding, it is highly customizable and scalable. It can additionally be used in applications for advanced Bay control/monitoring, frequency/voltage load shed, substation alarm concentrator, annunciator and controller, advanced automation schemes such as bus transfer, stand alone breaker protection and monitoring.

More Info Buy Now |
 |
| C70 Capacitor Bank Protection and Control System |
 |
 |
Integrated protection, control and monitoring for capacitor banks. Based on the well-established and proven UR relay platform, the C70 provides both bank and system protection schemes for shunt capacitor protection. The current and voltage-based protection functions are designed to provide sensitive protection for grounded, ungrounded single and parallel capacitor banks and banks with taps, for a variety of capacitor bank configurations. Combined with the sophisticated built-in control functions turn ON/OFF banks with relative ease and flexibility for automatic voltage regulation.

More Info Buy Now |
 |
| MIV II Voltage/Frequency Protection System |
 |
 |
Three-phase and ground voltage protection relay. The MIV II, a member of the M II Family of protection relays provides voltage, frequency or voltage and frequency protection for a wide range of applications.

More Info Buy Now |
 |
| MIN II Ground Protection System |
 |
 |
Complete numerical ground directional protection. The MIN II, a member of the M II Family of protection relays, provides directional protection on distributed networks.

More Info Buy Now |
 |
| RRTD Remote RTD Module |
 |
 |
Remote temperature monitoring of RTDs for metering and protection. The Remote RTD Module provides additional RTD temperature metering capabilities for the 369 and M60 Motor Protection Systems.

More Info Buy Now |
 |
| DDFR Distributed Digital Fault Recorder |
 |
 |
The DDFR™ is a Power System Fault Recorder that collects, archives and manages Disturbance and Fault information that is recorded by microprocessor-based protective relays distributed throughout your local power system.

More Info |
 |
| DGT Distributed Generation Trip Control |
 |
 |
The Multilin DGT Distributed Generation Trip Control solution enables fast and secure disconnect of renewable energy generators from the electrical power grid. The DGT solution delivers secure, swift and long distance transfer trip capabilities for enhanced safety, utmost reliability and maximum asset protection.

More Info Buy Now |
 |
| MIV Voltage/Frequency Protection System |
 |
 |
Three-phase and ground voltage protection relay. The MIV, a member of the M Family of protection relays provides voltage, frequency or voltage and frequency protection for a wide range of applications.

More Info |
 |
| MIW Directional Power / Loss of Field |
 |
 |
Directional power and loss of field protection for generators. The MIW, a member of the M Family of protection relays, provides directional power and loss of field protection for generators
of any size.

More Info |
 |
| MIN Digital Ground Protection |
 |
 |
Complete numerical ground directional protection. The MIN, a member of the M Family of protection relays, provides directional protection on distributed networks.

More Info |
 |
| CIO Remote CAN I/O Module |
 |
 |
Remote CAN Bus Input/Output module for the 650 Family of relays. The remote CIO module provides additional input and output capabilities for the GE Multilin 650 family of relays.

More Info Buy Now |
 |
| DBF Digital Breaker Failure |
 |
 |
The DBF is a digital breaker failure relay that provides phase and ground backup protection if the primary circuit breaker fails to clear a system fault.

More Info Buy Now |
 |
| DBT Digital Breaker Supervision |
 |
 |
The DBT is a digital relay that supervises the integrity of the breaker's tripping and closing circuits. The relay checks the continuity of the coil regardless of the status of the breaker (open or closed).

More Info Buy Now |
| |
|