Digital Energy Protection & Control Software
Protection & Control Online Store
Protection & Control Support
Protection & Control Press Room

Resources
  Brochures
  Specifications
  Support Documents
 
Related Links
  EnerVista Suite
  Launchpad
  Viewpoint Engineer
  Viewpoint Maintenance
  Viewpoint Monitoring
  Integrator
  Aggregator
  PMCS
 
 
EnerVista Integrator. Comprehensive Communication Engine for Rapid Integration Integrator




EnerVista™ Integrator enables seamless integration with GE Multilin devices for new or existing automation systems through tested, pre-configured memory maps. Integrator significantly reduces the time and effort required to obtain device, event and waveform data for integration with an HMI, SCADA or DCS system.

Key Benefits
  • Reduces integration effort and cost by over 90% versus other communications servers
  • Provides comprehensive, accurate and high quality data from devices through unique GE device application intelligence
  • Reduces resource requirements by archiving and centralizing fault data from relays and meters for fault analysis
  • Supports integration of third-party (non-GE) Modbus devices into OPC compliant monitoring systems
Key Features
  • Easy device setup through device communications
  • Rapid retrieval of device, event and waveform data from GE Multilin devices for communication to OPC clients
  • Comprehensive, factory tested memory maps for GE Multilin devices
  • Scalable communication with up to 1000 devices or 65000 points respectively
  • Reliable aggregation of event records from multiple GE Multilin devices into a single system wide Sequence-of-Event (SOE) record
  • Optimized performance and decreased commissioning effort through the use of Virtual Mnemonics to scale data points
 
     


 
OPC Server
EnerVista Integrator is designed to provide seamless integration of GE Multilin devices into any new or existing monitoring or control system. With tested, pre-configured memory maps for GE Multilin devices, EnerVista Integrator eliminates significant effort required for programming all of the mnemonics associated with HMI, SCADA and DCS system integration, greatly reducing the commissioning time and cost.

Device Setup

    Configuring GE Multilin devices in EnerVista Integrator is achieved through establishing communication with the device.

  • Supports user-friendly, intuitive configuration of devices similar to EnerVista Viewpoint Monitoring and EnerVista Setup software
  • Provides configuration settings for both serial or Ethernet communications
  • Tests communications to ensure accurate device configuration

Third-Party Devices

    EnerVista Integrator supports third-party (non-GE) devices that utilize Modbus RTU or Modbus TCP/IP, providing a simple way to incorporate all devices into a monitoring and control system.

  • Supports addition of Modbus RTU or Modbus TCP/IP third-party devices
  • Provides direct configuration of Modbus mnemonics
  • Results in reduced integration time for multiple installations of EnerVista Integrator by importing and exporting mnemonics files
  
User-friendly, intuitive setup similar to Enervista ViewPoint Monitoring/Setup software to connect devices via OPC.
   
 
Events
  Automated archiving of event and waveform data from GE Multilin devices ensures that there is always comprehensive data available for diagnosing power system events.

Event Logging

The event records from GE Multilin devices can be automatically downloaded from each device and stored in a system wide sequence of events record. EnerVista Integrator will continually poll each GE Multilin device to see if any new events have been added to that device's event record. Once a new event has been detected, the event record will be downloaded from the device to the system wide sequence of events record.

Event Viewing

    The Event Viewer centrally stores and displays information about preset and configured systems events. Each event in the record contains the following information:

  • Event Time
  • Source Type
  • Event Type
  • Event Cause
  • Source Name
  •  
    This data can be sorted by any of the fields indicated above.


    Create a comprehensive, centralized, system wide sequence of event records for analysis of power system faults.
 
Waveform
  The waveform (oscillography) files from GE Multilin devices can be automatically downloaded from each device and stored in a central data repository using Integrator. Similar to Event Logging, EnerVista Integrator will continually poll each GE Multilin device to see if any new waveform files have been created. Once a new waveform has been detected by EnerVista Integrator, the file will be downloaded from the device to the centralized data repository.

Waveform Viewing

View and analyze waveform fault data that has been recorded from a power system device in a time-based, phasor quantity or tabular view. This Waveform View utility provides functionality to:

  • Convert waveforms that were stored in Comma Separated Value (.CSV) format to COMTRADE compatible files (e.g. SR Family, PQM)
  • Merge and overlay waveforms that were recorded from multiple devices
  • Identify the harmonic content in the monitored parameters


  •  
    System Requirements - EnerVista Integrator




    Supported Devices