GE Digital Energy - Protection & Control
 
 
 
 
Protection & Control Online Store
Protection & Control Support
Protection & Control Press Room

Ensuring the integrity of the world's power systems

Protection & Control Products

Advanced protection and control across the power system
GeneratorTransformerTransmission LineBusDistribution FeederMotorMeter
  • Generator
    Unparalleled protection, control & diagnostics

    From the protection and control of utility generators to ensuring the safe interconnection of renewable energy sources to the grid, to synchronization and load shedding solutions using advanced automation, Multilin products and services work to maximize asset reliability and operational life.

    View Generator Protection Products

     
        G30, G60

    Advanced Generator Protection & Control

    Applications

    Medium and large generators

    Pumped storage applications

    Transformer in-zone applications

    Steam, hydraulic, combustion

    100% Stator & Field ground fault detection

     
        489

    Cost Effective Generator Protection

    Applications

    Industrial power generation

    Co-generation applications

    Shipboard power generation

    Primary or backup protection

     
    G650, W650

    Distributed Generation Protection & Control

    Applications

    Distributed generation

    Wind turbine and alternative energy

    Transfer trip applications

    Interconnection protection

  • Transformer
    Adaptive & sensitive transformer protection

    Utilizing advanced algorithms to detect abnormal conditions such as hottest-spot, aging insulation and transformer loss of life within the power transformer, Multilin protection relays allow operators to follow an as needed maintenance program reducing total life-cycle costs.

    View Transformer Protection Products

     
    T60

    Advanced Transformer Protection

    Applications

    Medium to large MV - HV transformers

    Auto-transformer banks

    Main & backup protection

    Up to five current sources (windings)

     
    T35

    Multi-Winding Differential Protection

    Applications

    Medium to large LV – MV transformers

    Main protection for distribution schemes

    Transmission schemes backup protection

    Transformer – bus protection for small distribution systems

     
    745

    high-Speed, Draw-out Protection

    Applications

    Medium to large HV, MV & LV transformers

    Main & backup protection for transmission & distribution

    Automatic tap-changer monitoring

    Auto-transformer banks

  • Transmission Line
    Setting the standard in transmission protection

    With real-time system monitoring tools utilizing synchrophasor measurement data, utilities are able to pursue demand response initiatives, implement remedial action schemes. Wide area protection, fault and disturbance analysis capabilities ensure utilities optimize and increase transmission reliability.

    View Transmission Line Protection Products

     
    D60, D90Plus

    Fast and Secure Distance Protection

    Applications

    Transmission & sub-transmission

    Single and three-pole tripping

    CCVT and magnetic VTs

    Series compensated lines

     
    L60, L90

    Unit Protection for Transmission Lines

    Applications

    Transmission & sub-transmission

    Single and three-pole tripping

    Digital communications (e.g. SONET)

    Power line carrier communications

    Phase comparison supports third party legacy devices

     
    D30, L30

    Cost Effective Line Protection

    Applications

    Transmission & sub-transmission

    Non-radial distribution feeders

    Industrial distribution feeders

    MV feeders with distributed generation

  • Bus
    Protecting power system convergence points

    Multilin protection and control devices offer true integration of features including protection, monitoring, metering, communications and control into one easy-to-use device. Our products ensure the required protection and control selectivity, and deliver the reliability needed for even the most complex bus configurations.

    View Bus Protection Products

     
    B90

    High-end Low Impedance

    Applications

    Bus schemes with up to 24 breakers

    Distribution, sub-transmission and transmission substations

    MV, HV and EHV systems

    Breaker failure and overcurrent protection

     
    B30

    Advanced Low Impedance

    Applications

    Bus schemes - up to 6 circuits & 2 zones

    Distribution, sub-transmission and transmission substations

    MV and HV systems

    Breaker failure & overcurrent protection

     
    MIB

    High Impedance

    Applications

    Switchgear and substations

    LV, MV, HV systems

    Restricted ground fault to machines and transformers

  • Distribution Feeder
    Immediate sensing and isolation to prevent hazards

    Improve power system safety and ensure efficient recovery of distribution networks through fault isolation, sectionalization and power system restoration schemes. From the detection of fallen power lines and damaged underground cables using Hi-Z detection, to incipient cable fault detection and arc flash mitigation, Multilin relays provide the high-speed sensing and isolation required to minimize system outages and ensure safety.

    View Distribution Feeder Protection Products

     
    F35, F60

    High-end, Multiple Feeder Protection

    Applications

    Multiple/single high-end feeders and Incomers

    Transfer schemes

    Recloser protection & control

     
    750/760, F650

    Comprehensive Feeder Protection

    Applications

    High-end feeders and incomers

    Transfer schemes

    Recloser protection & control

     
    350, 735/737

    Cost-effective Feeder Protection

    Applications

    MV/LV feeders

    Primary or backup protection

    MCCs & PDC LV systems

  • Motor
    Complete, Unmatched Motor Protection

    From protecting down hole pump motors to low voltage conveyor systems, Multilin relays provide the flexibility to meet industrial protection requirements. Coupled with advanced diagnostics, powerful automation and multiple communications options including support for IEC 61850, GE’s Multilin relays lead the industry in advanced motor protection.

    View Motor Protection Products

     
    469, M60

    The Standard in Motor Protection

    Applications

    Gas and liquid separation

    Lift pumps

    Wellhead monitoring

    Centrifugal pumps

     
    339, 369

    Monitor Your Motor's Health

    Applications

    Down-hole pumps

    High-inertia and two speed loads

    Compressors

    Booster stations

     
    MM200, MM300

    Advanced LV Motor Management

    Applications

    Refinery automation and control

    Belts and conveyor systems

    LV pump applications

    LV fan applications

  • Metering
    Power quality measurement & energy metering

    From basic metering to high-end transient capture and flicker detection, we offer a full range of commercial, industrial and utility grade meters. Multilin meters offer the energy metering and power quality measurement required to optimize and lower power system costs. With comprehensive communications, including support for industry standard protocols, Multilin meters can be easily integrated into new or existing DCS or SCADA systems. When coupled with GE’s EnerVista software, operators gain real-time access to power system status, alarms, and fault diagnostic and analysis tools.

    View Metering Protection Products

     
    EPM 6000

    Essential Power Monitoring

    Applications

    Supervisory Systems (SCADA) integration

    Distributed Control Systems integration

    Visual monitoring via built-in display

     
    PQM II

    Power Quality & Cost Management

    Applications

    Cost-center billing

    Energy profiling

    Demand dispatch

    Monitoring for renewable energy

     
    EPM 9650, EPM 9800

    Advanced PQ Analysis

    Applications

    Substation remote monitoring

    Power Quality monitoring of critical loads

    Energy and power billing


GE Multilin offers a wide range of services to assist with solutions to power protection challenges. Our PMCS Energy Management System enables economic and efficient energy use by optimizing the control of processes and equipment. Multilin Advanced Training Services provides high-quality courses including in-class training, on-site training, and Interactive Learning CDs. Our team of experienced Consulting Services Engineers can help with end-to-end solutions or designing, commissioning and maintaining protective systems and power system protection devices. Multilin Packages Solutions is a global one-stop solution for engineering and building customized relay panels.

 


EnerVista™ is an industry-leading suite of software tools designed to simplify working with Multilin devices. The suite consists of tools that streamline processes such as creating and validating settings files, integrating Multilin devices to Automation systems, and monitoring and controlling the equipment being protected. Launchpad is an industry leading device setup and document management toolset for Multilin protective relays. Viewpoint Engineer features Logic, IEC61850 system configuration and real-time monitoring. Viewpoint Maintenance provides comprehensive security auditing, device and asset health reporting and fault data retrieval. Viewpoint Monitoring is an easy-to-use monitoring and data recording toolset. Integrator delivers OPC connectivity to automation and historian applications