C90Plus - Design flexibility to simplify substation control
December 11, 2007
A powerful logic controller, the C90Plus has been specifically designed for the automation requirements of Utility substation environments and industrial power systems. Based on the URPlus platform of protection and control relays, the C90Plus simplifies substation automation engineering by delivering greater protection capabilities, performance and design flexibility.
Featuring advanced automation and control, bay protection and control, high accuracy digital fault recording, comprehensive communications and extensive HMI capabilities, the C90Plus represents the next benchmark in logic control.
Learn More Brochure Media Kit |
|
Multilink – High-port density switch supports large networks
October 26 , 2007
Now offering increased port density and advanced network management capabilities, the new substation hardened, Multilink ML2400 now supports up to thirty-two 10/10 Mbps copper or sixteen 10 or 100 Mbps fiber optic Ethernet Ports. With advanced 802.1 network management features, such as IPv6, this next-generation Ethernet switch easily integrates into new or existing infrastructures to reduce system costs.
Learn More Brochure Press Release |
|
EnerVista™ Viewpoint Monitoring - Supporting up to 150 devices
October 18 , 2007
Supporting larger systems with the ability to monitor up to 150 devices, or 9,000 data points, Viewpoint Monitoring integrate GE Multilin devices into a simple to use monitoring and control system. Incorporating powerful features such as plug-and-play functionality, pre-configured monitoring screens, trending, and customizable one line diagrams, Viewpoint Monitoring is the simple solution for achieving complete system visibility.
Learn More Brochure Press Release |
|
EnerVista™ Viewpoint Engineer - Graphical logic creation
October 18 , 2007
Providing an easy-to-use graphical drag-and-drop environment for logic creation, Viewpoint Engineer allows you to manage, configure, and test your Multilin UR and URPlus relays at a system level. Also featuring a vendor independent, IEC61850 Configurator, the implementation of GOOSE peer-to-peer communication across multiple vendors has never been easier.
Learn More Brochure |
|
EnerVista™ Integrator - Plug-and-play device integration
October 18 , 2007
With its plug-and-play functionality, EnerVista™ Integrator enables seamless integration of data from Multilin devices into new or existing automation systems. Supporting the latest in device firmware and Windows operating systems, Integrator greatly reduces the time and effort required to import essential data into your EMS, DCS, or SCADA systems.
Learn More Brochure |
|
RTT - Simplified protective relay and meter bench testing
September 27, 2007
The RTT Desktop Test Set is a compact, cost effective tool used to validate the operation and configuration of protective relays, meters and PLCs. The RTT Desktop Test Set provides single phase injection and real-time control of inputs for hands-on training of power system devices.
The RTT allows trainees to understand how devices operate under real injection conditions and provides this control in a package that is cost effective enough for every student to have one at their disposal.
Learn More Brochure Media Kit |
|
D90Plus - Most advanced line protection system on the market
August 23, 2007
The Multilin D90Plus, is designed as a single-platform solution for the protection of MV to EHV transmission lines. As a sub-cycle distance relay, the D90Plus offers true convergence of functions, including advanced automation and control, digital fault recording, comprehensive communications and extensive local HMI capabilities.
The D90Plus eliminates the need to have multiple stand-alone devices resulting in significant savings in installation, commissioning, maintenance and lifetime costs.
Learn More Brochure Media Kit |
|
M60 - The new standard for motor protection
July 17, 2007
The M60 Motor Protection System offers advanced Motor Health Diagnostics including a Sequence of Events recorder and data logger. This provides unparalleled access to motor and system operating characteristics, thereby enabling preventative maintenance planning, reducing unplanned shutdowns and minimizing critical asset losses.
With a customizable motor thermal model and one of the most complete motor protection feature sets available in the industry, the M60 sets the new standard in motor protection systems.
Learn More Brochure Media Kit |
|
G60 - Generator protection system with Synchrophasors
July 17, 2007
Exceeding the latest IEEE C37.118 standard for Synchrophasor measurement devices, the G60 provides Synchrophasor streaming over Ethernet as well as triggered records of Synchrophasor data.
Coupled with advanced protection and control features such as Accumulated Over / Underfrequency and enhanced RTD protection, the G60 allows power provides to identify and prevent impending generator and network stability issues.
Learn More Brochure Media Kit |
|
UR Family - Raising the bar in Ease-of-Use
July 17, 2007
In the industry, products protecting and controlling power systems assets normally require hours of extensive programming to customize protection settings and control logic to a particular application. GE Multilin continues to take ground-breaking steps to simplify and streamline this process.
Learn More Brochure Media Kit |
|
DDFR - The next evolution in digital fault recording
June 28, 2007
The new DDFR provides a complete fault recording system that collects and manages the fault and disturbance records found in digital protective relays distributed across a substation at a fraction of the cost of a traditional, stand-alone, centralized digital fault recorder.
Learn More Brochure Media Kit |
|
Enhanced 369 - Monitor your Motor’s Health
June 12, 2007
The enhanced 369 Motor Protection System eliminates the need to manually program hundreds of individual protection settings using the exclusive six-step 369 Motor Settings Auto-Configurator. With its detailed and graphical Motor Health Report operators can “see” how the motor is operating, enabling preventative maintenance planning.
Unplanned shutdowns can be minimized using the large capacity Event Recorder and Motor Start Data Logger that captures graphical oscillography records and start/stop waveforms.
Learn More Brochure Media Kit |
|
MM300 - Compact & fully loaded Motor Manager
May 1 , 2007
GE Multilin, one of the most trusted names in motor protection and control, introduces the new MM300 Low Voltage Motor Manager – motor protection and control system for LV NEMA and IEC motor applications. With advanced health diagnostics and single-click access to device & Status information, the MM300 works to extend equipment life, increase system reliability and maximize process uptime.
Learn More Brochure Media Kit |
|
MDS - Rugged Wireless Communications
January 12, 2007
MDS wireless technology - combined with Multilin’s product lines in protection, metering, control and automation systems - offers customers improved asset protection and control through enhanced security, speed and access of information. MDS technology helps Multilin customers to significantly reduce the cost of system interconnection, commissioning, and maintenance costs while increasing overall system performance and uptime.
Learn More Press Release |
|
MIWII - Directional Power Protection System
November 5, 2006
The MIW II, a member of the M II family of protection relays, is designed as a microprocessor based relay, providing directional power and loss of field protection for generators. Reduce your troubleshooting and maintenance costs with MIW II’s automatic display of last fault information, event recording, and oscillography waveforms.
Learn More Press Release |
|
C70 Capacitor Bank Protection & Control System
October 13, 2006
The C70 is an integrated protection, control and monitoring device for capacitor banks based on the well-established and proven GE Multilin UR relay platform.
The
C70 provides both the bank and system protection schemes for shunt capacitor protection.
Combined with the sophisticated built-in control functions, capacitor banks can be turned ON/OFF with relative ease and flexibility for automatic voltage regulation.
Learn More Brochure Press Release |
|
D60, L90, N60 - Synchrophasor with Transmission Protection
October 3, 2006
The introduction of a synchrophasor option with the line distance (D60) and line current differential (L90) protection systems give users the choice to have integrated protection and Phasor Measurement Unit (PMU) or standalone PMUs (N60) according to their needs. Thousands of existing D60 and L90 users can easily upgrade their relays to PMU option with a simple upgrade package from GE Multilin.
Learn More Press Release |
|
G650 - Generator Protection and Control
August 1, 2006
The G650 is a distributed generation protection and control system designed for small to medium sized generators. The G650's enhanced protection options ensure it will fit your generator protection requirements, delivering complete distributed generator interconnection protection.
Meeting international protection standards, coupled with enhanced fault recording and communications capabilities, the G650 is a cost-effective, reliable and simple solution.
Learn More Brochure Press Release |
|
| |
| |
|